Power model and estimates
Power Management configures display-off, automatic sleep, and idle lock on managed endpoints. Energy Analysis estimates electricity consumption and cost from endpoint activity durations and a power model. Policy coverage, actual execution, and estimates are different; an estimate is not a meter reading or proof of savings.
For policy configuration details, see Energy-saving policy.
Before You Begin
- Viewing estimates requires endpoint-management read permission. Changing the energy policy and power model requires the respective policy-management or operation permission. Confirm licensing and administrator visibility; for new data, check Windows endpoint enrollment and activity reporting.
- Assess effects on continuous jobs, remote access, and users; record prior settings and recovery arrangements. Start with controlled pilot endpoints rather than applying changes to everyone.
- Viewing existing activity estimates does not necessarily require an enabled energy policy; viewing existing coverage does not require changing one. To verify energy settings, first check the applicable configuration.
Configure and Verify the Policy
To verify energy settings or policy coverage, first check pilot endpoint scope, effective time and the energy-saving switch under UEM > Policy, as well as display-off, automatic-sleep and idle-lock times. Reuse suitable settings; only if necessary should an authorized person assess business impact, adjust them using Energy saving policy and wait for endpoint receipt. Coverage or a save does not prove execution; verify each setting on a pilot endpoint.
Configure the Power Model
If the existing power model meets the estimation requirement, view results without saving it again. Only when a change is needed should a person with the appropriate operation permission follow the steps below; record the old values and impact on other estimates first.
- Under Unified Endpoint Management applications, open “Energy Analysis” and select “Power model”. The model is used for the organization’s estimates; it does not distribute the policy or directly change endpoint power use.
- Enter verified assumptions for “Active power”, “Idle power”, “Locked power”, and “Price per kWh”. Each power value must be greater than 0 and at most 10000 W; price must be between 0 and 1000. Use a consistent price unit and document assumptions rather than treating examples as actual billing.
- Save, reopen, and check the values. Changing the model affects historical and current estimates recalculated with it; record model, time range, and endpoint scope before comparison.
Review Results and Troubleshoot
- Select
24H,7D, or30D;7Dis initial. Time buckets and the local time zone affect boundaries, so check the range before comparison. - Review policy-covered endpoints, observed duration, estimated electricity, and estimated cost. Filter endpoint details by keyword or policy coverage. Coverage reflects applicable effective settings, not confirmed endpoint execution; settings that are all “Never” do not count as effective coverage.
- If details are empty or observed time is low, check permissions, endpoint authorization and Windows status, time range, and activity reporting. Missing records do not mean zero consumption. If estimates differ from bills, check model, price, time, and scope and cross-check actual metering or invoices.
The keyword and policy-coverage filters apply only to the endpoint details list; they do not recalculate the summary at the top using those filters. The summary still covers eligible endpoints visible to the administrator for the selected time range. Filtered details or the current page may therefore not add up to the summary. Check time, endpoint scope and filters before comparing.