Review endpoint power events
Power-event records help review managed endpoint startup and shutdown. They are not a continuous online-status record and cannot alone prove employee attendance or the exact time power was lost.
Prepare and query
- Confirm UEM viewing permission and that the enrolled endpoint is within the administrator's visible scope; export also requires export permission. To verify a new event, check the pilot endpoint's client and reporting status. This task does not require a separate power-event policy, but collection and reporting depend on the environment.
- Open Power Events under UEM > Audit. The initial query includes the current day and the previous 29 days; adjust the dates as needed. The list shows group, endpoint name, IP, startup or shutdown event, and time.
- Search the loaded page by endpoint, group, address, event, or time. Keywords and sorting affect only that page. Clear the keyword and check each page if needed. The total and visible row count can differ because the page displays only startup and shutdown events. The server returns the current page before the page filters for startup and shutdown. Even with no keyword and a positive total, a page may have no visible rows. Check other pages; exporting an empty page may also produce a file with no data rows.
- To verify a new record, with authorization, perform a controlled startup or shutdown on a pilot Windows endpoint. Once the client runs and reports, query the event and compare it with system events and the actual operation time. Verify coverage on other platforms separately.
Changing or clearing the keyword or changing the date range returns the list to the first page. Select another page again if needed. If the page reports that logs could not be loaded, the list is cleared. Check permissions and service availability, then query again; do not treat the empty list as a successful result.
Export and limitations
Select Export to create a CSV containing only startup and shutdown rows on the currently loaded page after keyword filtering, not every record in the date range. Check permission, page, and filter before exporting; verify the file and protect it according to organizational requirements. Manual table sorting does not determine the order of rows in the export; sort the file after export if a specific order is needed.
The Windows client reads system events when it runs. If it cannot obtain a valid event time, the recorded time may instead be when the record was created. Unexpected power loss, missing system logs, a stopped client, or reporting failures may also cause gaps or differences. Corroborate actual times with system records, endpoint state, and on-site information. An empty result does not prove the device was not started or shut down.
Updated